Additional Features:
Cancel code feature
Installer walk test feature
Real time clock with reminder when time needs to be reset
Chime on/off feature through keypad
Keypad tamper function with optional CS transmission
Swinger shutdown option
System stabilization time prevents false alarms during powerup
NFPA temporal bell
Arm while faulted
Supervised bell output
78 Event Log
Paging Format
User Codes:
15 user codes:
Ambush and door strike codes
Open/close by user ID
Unique O/C codes for all users
Programming/Remote Operations
(Return to top)
Remote commands include:
Arm, disarm, bypass zones, change user codes, read system
status
Remote operations can be performed through PC Downloader Upload/download
remote operations of all system features and functions. ALL ON
A SINGLE CALL. With FBII Answering Machine Bypass
Remote and/or unattended downloading On-site programming directly
through keypad (LED or LCD)
CSID and installer code, anti-takeover feature
Keypads:
Individual LEDs show status of each zone with indications
of ALARM, TROUBLE BYPASS and NOT READY conditions
English LCD keypad displays system status in 2 line by 16 character
readout with customized 12 character zone descriptors (LCD keypads
include XK5LC and XK7LC)
Central Station Communications:
Two CS account numbers (3 or 4 digits):
Pulse formats include: 3x1, 4x1, 4x2,Expanded: Speeds 10,
20, 40PPS with or without parity
FBI Superfast, Ademco Express 4x1 and 4x2 Formats, Ademco CID
Format Split and dual reporting option for openings and closings
Test options include daily, weekly, 27, 60 or 90 day, hourly
intervals test by time, event
Power Specifications:
Watchdog circuitry insures integrity of microprocessor
Total aux. power: 500 mA. regulated
Transformer: 12V 20VA
Listings:*
Residential UL Household Combination Burglary/Fire
(XL-2T)
UL Mercantile Burglary Listing: Local Grade A, Police Connect
Grade A, Grade AA
California State Fire Marshal (CSFM)*
|