Sales - Service - Installation - 24 Hour U.L. Approved Monitoring
Phone 860-645-6500 - Toll Free 1-877-737-6500 - Fax 860-643-5591

CADDX | FBI 4600 & XL-2 | MA 850-854-900 | MA800 | ADEMCO Vista
MA825 | MA1008 - 1010 - 1016 | DSC1555 | CADDX NX-8

 NAPCO
MA1008-1010-1016

 

MA 1008, 1010, 1016
TO DISARM:
Enter your code into the keypad, if you enter a wrong code, you must wait at least 2 seconds before you try again.

TO RESET:
Hold down #9 till it beeps.

TO CHANGE CODE:
Hold down the 8 key till it beeps. Enter your program code into keypad, the top 3 lights will flash and sounder will pulse. Press S key enter user # (1-5) then enter 4 digit code (1-9). EX: press (S) + 1 + four digits - user 1's code. To erase code press S plus user # (1-5) to be erased. EX: press (S) + 2 - user 2's code erased. to end program mode press S key twice.

TO BYPASS:
Hold down the number 9 until it beeps, then enter the code to arm or press S and then zone number to bypass and then enter the code to arm.

FLASHING GREEN LIGHT:
This means a zone is open or in trouble, hold down the number 3 key to display zone then try to close and reset. If unable to restore zone in trouble then press (s) key & the number of the zone (1-8) to be shunted. Hold down the 2 key to display shunted zone.

TOP 3 LIGHTS BLINKING:
This means you have lost A.C. power. Check for general outage or for disconnected transformer. If you must arm the system without power, hold down 9 till it beeps to stop blinking lights before arming.