TO DISARM:
Enter your code at keypad. If erroe is made, you must wait
5 seconds before re-entering.
TO ARM:
Close all protected doors and windows, even the door near
the keypad. Wait for solid green light & then enter your
code. Wait for red armed light & then exit (30 seconds).
TO FIND OPEN ZONE:
Green light will be flashing. Push (3) and hold down until
it beeps (about 5 seconds). Open zone will show in display. If
unable to clear zone, see to bypass below.
TO BYPASS OR SHUNT:
Press (S) plus zone # you wish to bypass. The yellow light
will come on. Enter code, red and yellow light will be on.
RESET SMOKE/FIRE:
Enter code twice to silence. Determine what caused alarm,
vent smoke by opening windows, doors, etc., when clear, push
(9) and hold until it beeps. Red fire light on keypad should
shut off within 60 seconds.
* If fire reset fails first time call service*
TO CHANGE CODE:
Press (8) and hold until it beeps. Enter program code (usually
5-4-3-2-1), then push (S), then the user # (1,2,3,OR 4), then
enter new 4 digit code. Repeat for up to 4 users. When done enter
(S)(S).
LIGHTS FLASHING:
If all lights are flashing on keypad this indicates A.C.
power loss to control. This could be caused by power failure,
fuses blown, circuit breaker tripped, or transformer is unplugged.
If system needs to be armed, hold down #9 until it beeps. System
may now be armed if needed. Lights will continue to reflash every
10 minutes until power is restored.
KEYPAD BEEPING:
If the keypad is beeping and an alarm has not been triped,
it could be due to being in test mode, or the door chime is activated.
Push (9) and hold until it beeps.
DISPLAY SHUNT:
Push (2) and hold until it beeps. Zones that have been shunted
will show in the display.
DISPLAY OPEN ZONE:
Push (3) and hold until it beeps. Zones that are open will
show in the display.
INSTANT PROTECTION:
Push (4) and hold until it beeps. This will cancel the entry
delay. Only for use while at home.DISABLE
SHUNTS:
Arm the system, then disarm it. This should cancel any shunted
zones.
TEST BATTERY/SIREN:
Push (1) and hold until it beeps. The siren should sound
for 5 seconds & then shut off. Central station will not be
notified. This test checks power, battery & siren.